美隆電子有限公司

Mayloon Electronic Co., Ltd.,

  • 增加字體大小
  • 預設字體大小
  • 減少字體大小

Cement Resistor - SQM Type

按圖放大 水泥電阻

PDF File  Data Spec Cement Resistor - SQM Type

Cement FEATURE

  • Exceptionally small and sturdy, mechanically safe.  
  • Excellent electrical characteristic  
  • Tolerance of ±5% and ±10% are standard.  
  • Non-inductive type are available on request.  
  • Heat and flame resistance   
  • The materials used and the construction techniques ensure excellent   flame resistance, arc resistance and moisture resistance as well as self-extinguishing capabilities, They will withstand the most rigorous loading test.
  • As resistors in radio and television receiver, The hazardous conditions of  smoking and reheat can be completely prevented by the proper choice of power resistors.
  • For high resistance value, The winding core will be replaced by metal oxide film core (RS Type)
  • Applicable specifications: EIA RS-344 and EIA RC-649 


Cement Type : SQM

  1. Power: 2W Wire Wound 0.01~50  Metal oxide 50~50K Ω
  2.  Power: 3W Wire Wound 0.01~50  Metal oxide 50~50K Ω
  3.  Power: 5W Wire Wound 0.01~50  Metal oxide 50~50K Ω
  4.  Power: 7W Wire Wound 0.01~100  Metal oxide 100~47K Ω
  5. Power : 10WS Wire Wound 0.01~100  Metal oxide 100~47K Ω
  6. Power: 10W Wire Wound 0.01~100  Metal oxide 100~47K Ω

 

更多

水泥電阻

 
歡迎您瀏覽本網站 WELCOME TO MAYLOON
Mayloon Electronic Company Limited Mayloon Lighting Company Limited

Mayloon on-line chat now

即時業務接洽
WhatsApp:91808452
QQ:1247069489
E-mail: peter@mayloon.com
TEL:852-2408 9788 M: 9180 8452

消息

美隆照明有限公司
承接換燈照明工程:
更新換舊
各類型照明燈具
瑩光燈管換LED燈管
包括:燈管支架/有罩燈盤/格柵燈盤等
歡迎來電查詢
MP.:91808452

Newsflash

換燈管
照明節能改善計劃
LED (T8) 室內照明燈 [更新換舊方案]
工程方案:
T8日光燈管 換裝 LED 燈管
保留原有燈具,取下舊燈管,只須重新接駁電線換上LED燈管。
節能效益比較
T8日光燈管 T8 LED發光效率(lm) 慳電效率(%)
23W(2ft) 8W-10W (2ft)  >750lm 50-70%
45W (4ft) 15W-20W (4ft) >1500lm 50-70%
電費計算 (瓦X時間X $)  1000W*1hrs=1deg.
換裝 LED 燈管後之效益
1. 耗電量減少: 55%-70% (節能環保)
2. 照亮度: 提升54%. (可選擇性亮燈數量二次節能)
3. 室內溫度: 降低約2度 (減輕冷氣負荷)
美隆照明產品 現場測試比較換裝燈管 前/後 流明 (lux)
改裝前(螢光燈管) 改裝後(LED 燈管) 結果
換裝前T8燈管 照度 52 Lux 換裝後T8燈管 照度 80 Lux 亮度提升54%
量測出燈管功率 42W 量測出燈管功率 21W 降低耗電50%
耗電: 1.008deg (24hrs) 耗電: 0.504deg (24hrs) 節能達50%

試例: 計算100支T8燈管 換裝LED燈管後 慳電效率
T8 (4Ft) 42W 燈管 52lux T8 (4Ft) 21W 燈管 80lux
總瓦: 4,200W /set 總瓦: 2,100W /set
耗電量: 100.8deg/Day 耗電量 50.4deg/Day
電費: $0.934x100.8= $94.15/day 電費: $0.934x50.4 = $47.1/day
電費: $2,824.50/month 電費: $1,413.00/month
一年電費 HK$33,894.00 一年電費 HK$16,956.00
回報率(ROI) : 50% 。

註: 1. 電費參考中電電費單價格計算。
2. 本方案沒有計算日光燈管二年耗損(買燈及維護)支出。
工程訊息 市場消息
欲索取更多詳細方案資料請聯絡本公司業務經理 852-24096712

Youtube 換燈-安美大廈