美隆電子有限公司

Mayloon Electronic Co., Ltd.,

  • 增加字體大小
  • 預設字體大小
  • 減少字體大小

SS12 - S100

按此還有更多 1A Surface Mount Schottky Barrier Diode

PDF File 1A SS12-S100 (20V-100V) SMA/DO-214AC

SINLOON® 肖特基穩壓二極管 SS12 - S100  (20V~100V)
Case: SMA/DO-214AC 1.0A SMT Schottly Barrier Diode
Feature Mechanical Data
Schottky Barrier Diode Case: SMA/DO-214AC, Molded Plastic
Guard ring die construction Mounting : Type Number
Low Forward Loss, High efficiency Weight: 0.064 grams (approx)
For use in low voltage application Polarity: Cathode Band or Cathode Notch
Surge Overload Rating to 30A Peak Terminals: Solder Plated, Solderable per MIL-STD-750, Method 2026.
Ideally Suited for Automatic Assembly Lead Free: For RoHS / Lead Free Version Add “-LF” Suffix to part Number.
Plastic Case Material has UL Flammability Classification Rating 94V-0)
Maximum Ratings and Electrical Characteristics @TA=25 unless otherwise specified
Characteristics Symbol SS SS SS SS SS SS SS SS Unit
12 13 14 15 16 18 19 100
Peak Repetitive Reverse Voltage VRRM 20 30 40 50 60 80 90 100 V
Working Peak Reverse Voltage VRWM
DC Blocking Voltage VR
RMS Reverse Voltage VR(RMS) 14 21 28 35 42 56 64 71 V
Average Rectified Output Current @TL=75 IO 1.0 1.0 1.0 A
(JEDEC Method) IFSM 30 30 30 A
Forward Voltage @IF=1.0A VFM 0.5 0.7 0.85 V
Peak Reverse Current @TA = 25 IRM 0.5 0.5 0.5 mA
At Rated DC Blocking Voltage @TA=125 20 20 20
Typical Thermal Resistance (Note 1) RθJL 25 28 28 pF
RθJA 88 88 88 ℃/W
Operating Temperature Range Tj -65 to +150
Storage Temperature Range TSTG
Note : 1). Mounted on P.C. Board with 5.0mm2 copper pad area. Return to Schottky Diode First Page
 
歡迎您瀏覽本網站 WELCOME TO MAYLOON
Mayloon Electronic Company Limited Mayloon Lighting Company Limited

Mayloon on-line chat now

即時業務接洽
WhatsApp:91808452
QQ:1247069489
E-mail: peter@mayloon.com
TEL:852-2408 9788 M: 9180 8452

消息

美隆照明有限公司
承接換燈照明工程:
更新換舊
各類型照明燈具
瑩光燈管換LED燈管
包括:燈管支架/有罩燈盤/格柵燈盤等
歡迎來電查詢
MP.:91808452

Newsflash

應急照明 裝置位置

緊急照明

應急照明

 

有圖應急照明 裝置位置

微波感應開關

 

(1)消防應急標誌燈。其位置設在太平門頂部和疏散走道及其轉角處距地面高度1m以下的牆面,採用單應急方式,火災時由消防控制室發出信號接通。

(2)消防應急照明迴路。該迴路的照明平時起正常公共照明的作用,可通過照明開關控制。火災時能轉入應急狀態,直接接通應急疏散照明燈具,此時開關處於失控狀態,消防應急照明不受開關控制。

(3)一般公共照明迴路。此類照明是一般公共照明,不屬應急照明,故可不接在帶蓄電池的迴路,火災時也不要求立即接通。該類照明接在事故照明配電箱的普通迴路可節省單獨設置配電箱的費用,不增加蓄電池的容量,管理比較方便。

(4)根據實際工程需要,應急電源配電箱還可以提供消防控制所需要的直流電源。

(5)對變配電室、消防控制室、消防水泵房、防煙排煙機房,供消防用電的蓄電池室、自備發電機房、電話總機房、計算機房及發生火災仍需堅持工作的重要房間,應單獨設置應急電源箱,應急照明應保證平時正常照明的照度。